loading
IPON LED  >  AI - Page Sitemap  >  IPON LED led driver dimming IPON for Lighting control system
IPON LED led driver dimming IPON for Lighting control system

IPON LED led driver dimming IPON for Lighting control system

Price
Get Latest Price
Get the latest price
Quantity Needed:
Pieces
E-mail:
Product Information of IPON LED led driver dimming IPON for Lighting control system

150W Waterproof CV DALI Driver

- Model: IP1WxxV-C150XY-0MWWZ
- Input Voltage: 100-277VAC**
- Output Power: 1
- Output Channels: 1

150W Constant Voltage Waterproof LED Driver IP1WxxV-C150XY-0MWWZ

IP1WxxV-C150XY-0MWWZ series are constant voltage mode output LED driver. The series of products are suitable for outdoor because of IP67 and great surge immunity. The user can select corresponding model according to the dimming method and market requirements.

Features

1. Supply voltage: 100-277VAC or 141-391VDC

2. Great surge immunity 10kV

3. PWM output frequency >1kHz

4. 100,000Hour life @ Tc=75C

5. 7 year warranty @ Tc<=80C

6. 0-10V/PWM/DALI (optional) dimmable

7. 2% minimum dimming output

8. Dim off with 0.5W standby

9. 12V 300mA auxiliary power to power controllers and fans (optional)

10.Input over voltage protection (optional)

11.CB/CCC SELV output

12.Safety according to EN 61347-1, 61347-2-3,61347-2-13, 62384

13.Application :strip lights, landscape lights, bay lights, street lights, flood lights

Model List

Model Number

Input Voltage Range

Output Power

Output Voltage

Output Current Min.

Output Current Max.

Certificates

IP1W24V-C150XY-0MWWZ

100-277VAC

150W

24V

0

6.25A

FCC/CCC/CB

IP1W36V-C150XY-0MWWZ

100-277VAC

150W

36V

0

4.2A

FCC/CCC/CB

IP1W48V-C150XY-0MWWZ

100-277VAC

150W

48V

0

3.2A

FCC/CCC/CB

 

XY=

Dimming Method

Programmable

12Vaux

Dim-off

NN

-

-

-

-

AN

0-10V

-

-

EN

0-10V

-

DN

DALI

-

-

 

Z=


U

UL cable with ground wire

S

VDE cable/Class I




Technical Parameter

Model

IP1WxxV-C150XY-0MWWZ

Output

Channels

1

Voltage accuracy

±3%Vo

Output overshoot

10% Vo, max.

Input

Voltage

100VAC – 277VAC

Frequency

50/60Hz

Current

1.4Amax@120VAC & Full-Load,

0.75Amax@220VAC & Full-Load

Inrush current

65A peak, 1.2ms duration, <0.25A2s@230VAC, Cold Start
70A peak, 1.3ms duration, <0. 5A2s@277VAC, Cold Start

PF

>0.9@60-100%load, refer to PF vs. Load curve

THD

<15%@60-100%load, refer to THD vs. Load curve

Leakage Current

1mA max @277VAC 60Hz, UL8750,

0.75mAmax @240VAC 50Hz, IEC61347-1

Protection

Input under voltage

Shut down and auto-restart

Input over voltage

*Optional: Shutdown @320VAC

Output over current

120% Io, typ.

Short circuit

Auto recovery. The output recovers when short is removed.

Over temperature

Lower the output current when Tc≧105±10℃; Auto Recovery When Tc≦70±10℃

Others

Setup time

1.2s max.

Surge protection

Line to line 4kV, line to ground 10kV, IEC 61000-4-5

Operating temperature

-40℃+90℃10%RH100%RH

Storage temperature

-40℃+85℃ 5%RH100%RH

MTBF

≥320,000 hours, 75℃ case temperature (MIL-HDBK-217F)

Lifetime

≥100,000 hours, 75℃ case temperature

Case temperature

90℃ max, marked in the Tc point of label

Dimensions

6.34x2.66x1.32 by inch (body),   7.40x2.66x1.32 by inch(endcaps included)

161.0x67.5x33.5 by mm (body), 188.0x67.5x33.5 by mm (endcaps included)

Net weight

800g

Packing

20pcs/Carton/17kg, 500x320x315mm

Notes: Unless specified, all the test results are measured in 25℃ room temperature.

* marked items are optional and contact with sales people to get the functions.